<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>VRF Sistemler &#8211; mitsubishi heavy klima</title>
	<atom:link href="https://mitsubishiheavyklimalar.com/vrf-sistemler/feed/" rel="self" type="application/rss+xml" />
	<link>https://mitsubishiheavyklimalar.com</link>
	<description>mitsubishi heavy klima fiyatları</description>
	<lastBuildDate>Fri, 10 Apr 2026 06:35:05 +0000</lastBuildDate>
	<language>tr</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	

<image>
	<url>https://mitsubishiheavyklimalar.com/wp-content/uploads/2026/01/cropped-logo-mitsibushi-yetkili-bayi-32x32.jpg</url>
	<title>VRF Sistemler &#8211; mitsubishi heavy klima</title>
	<link>https://mitsubishiheavyklimalar.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>FDC1350KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc1350kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:14 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1175</guid>

					<description><![CDATA[<p>Mitsubishi FDC1350KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1350kxzre2-vrf-isi-pompasi/">FDC1350KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">450KXZRE2 +<br />
450KXZRE2 + 450KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">48HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">15,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">96,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">135,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">135,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">43,41</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">34,17</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x4050x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">1116</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;3</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø19.05(3/4&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø38.1(1<br />
1/2&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4”)[ø28.58(1 1/8”)]</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~130</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1350kxzre2-vrf-isi-pompasi/">FDC1350KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC1250KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc1250kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:14 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1174</guid>

					<description><![CDATA[<p>Mitsubishi FDC1250KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1250kxzre2-vrf-isi-pompasi/">FDC1250KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">400KXZRE2 +<br />
400KXZRE2 + 450KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">44HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">15,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">92,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">125,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">125,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">37,59</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">30,91</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x4050x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">1116</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;3</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø19.05(3/4&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø38.1(1<br />
1/2&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4”)[ø28.58(1 1/8”)]</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~130</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1250kxzre2-vrf-isi-pompasi/">FDC1250KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC1200KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc1200kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:14 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1173</guid>

					<description><![CDATA[<p>Mitsubishi FDC1200KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1200kxzre2-vrf-isi-pompasi/">FDC1200KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="37">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">400KXZRE2 +<br />
400KXZRE2 + 400KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">42HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">15,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">90,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">120,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">120,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">34,68</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">29,28</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x4050x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">1116</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;3</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø19.05(3/4&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø38.1(1<br />
1/2&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4”)[ø28.58(1 1/8”)]</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~130</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1200kxzre2-vrf-isi-pompasi/">FDC1200KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC1060KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc1060kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:14 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1172</guid>

					<description><![CDATA[<p>Mitsubishi FDC1060KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1060kxzre2-vrf-isi-pompasi/">FDC1060KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">500KXZRE2 +<br />
560KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">38HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">16,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">82,6</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">106,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">106,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">34,51</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">27,62</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x2700x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">840</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;2</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø19.05(3/4&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø38.1(1<br />
1/2&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4”)[ø28.58(1 1/8”)]</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~130</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1060kxzre2-vrf-isi-pompasi/">FDC1060KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC1000KXZRE VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc1000kxzre-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:14 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1171</guid>

					<description><![CDATA[<p>Mitsubishi FDC1000KXZRE VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1000kxzre-vrf-isi-pompasi/">FDC1000KXZRE VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">500KXZRE2 +<br />
500KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">36HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">16,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">82,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">100,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">100,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">30,40</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">25,38</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x2700x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">840</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;2</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø15.88(5/8&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø38.1(1<br />
1/2&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø28.58(1<br />
1/8&#8243;)</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~130</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc1000kxzre-vrf-isi-pompasi/">FDC1000KXZRE VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC670KXZRE2 VRF Isı Pompası Dış Ünite</title>
		<link>https://mitsubishiheavyklimalar.com/fdc670kxzre2-vrf-isi-pompasi-dis-unite/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:13 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1165</guid>

					<description><![CDATA[<p class="text-uppercase alt-font text-extra-dark-gray margin-20px-bottom font-weight-700 md-w-100 justify-content-between">FDC670KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc670kxzre2-vrf-isi-pompasi-dis-unite/">FDC670KXZRE2 VRF Isı Pompası Dış Ünite</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table class="table table-striped" style="width: 100%;" border="0" width="719" cellspacing="0" cellpadding="0">
<colgroup>
<col style="mso-width-source: userset; mso-width-alt: 5193; width: 107pt;" width="142">
<col style="width: 82pt;" span="3" width="109">
<col style="mso-width-source: userset; mso-width-alt: 9142; width: 188pt;" width="250"> </colgroup>
<tbody>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Nominal kapasite</td>
<td class="xl65" style="border-left: none; width: 82pt;" width="109">&nbsp;</td>
<td class="xl66" style="border-left: none; width: 188pt;" width="250">24HP</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Güç kaynağı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">&nbsp;</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Başlangıç Akımı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">A</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">8</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Max. Akım</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">A</td>
<td class="xl67" style="border-top: none; border-left: none; width: 188pt;" width="250">42.4</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl69" style="border-bottom-width: 1pt; border-bottom-color: black; height: 31.5pt; border-top: none; width: 107pt;" rowspan="2" width="142" height="42">Nominal kapasite</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">Soğutma</td>
<td class="xl69" style="border-bottom-width: 1pt; border-bottom-color: black; border-top: none; width: 82pt;" rowspan="2" width="109">kW</td>
<td class="xl67" style="border-top: none; border-left: none; width: 188pt;" width="250">67.0</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; border-left: none; width: 164pt;" colspan="2" width="218" height="21">Isıtma</td>
<td class="xl67" style="border-top: none; border-left: none; width: 188pt;" width="250">63.0</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl74" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 189pt;" colspan="2" width="251" height="21">Elektriksel Özellikler</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">Soğutma</td>
<td class="xl69" style="border-bottom-width: 1pt; border-bottom-color: black; border-top: none; width: 82pt;" rowspan="2" width="109">kW</td>
<td class="xl68" style="border-top: none; border-left: none; width: 188pt;" width="250">25.57</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl76" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 189pt;" colspan="2" width="251" height="21">Güç Tüketimi</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">Isıtma</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">17.45</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Dış Boyutlar</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">YxGxD</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">mm</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">2052x1350x720</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Net Ağırlık</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">kg</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">420</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Ses Güç Seviyesi</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">Soğutma/Isıtma</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">dB(A)</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">65/64</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Soğutucu Akışkan</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">Tipi&nbsp;</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">&nbsp;</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">R410A</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Akışkan Şarjı</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">&nbsp;</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">kg/TCO2Eq</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">11.5<br />
/ 24.012</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Boru Bağlantıları</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">Likit Hattı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">mm(in)</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">ø12.7(1/2”)</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Boru Bağlantıları</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">Emme Gaz Hattı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">mm(in)</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">ø28.58(1<br />
1/8”)</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl65" style="height: 15.75pt; border-top: none; width: 107pt;" width="142" height="21">Boru Bağlantıları</td>
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; border-left: none; width: 164pt;" colspan="2" width="218">Basma Gaz Hattı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">mm(in)</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">ø25.4(1”)<br />
[ø22.22(7/8&#8243;)]</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Kapasite Bağlantı Aralığı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">%</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">50~160</td>
</tr>
<tr style="height: 15.75pt;">
<td class="xl71" style="border-right-width: 1pt; border-right-color: black; height: 15.75pt; width: 271pt;" colspan="3" width="360" height="21">Bağlanabilir İç Ünite Sayısı</td>
<td class="xl65" style="border-top: none; border-left: none; width: 82pt;" width="109">&nbsp;</td>
<td class="xl66" style="border-top: none; border-left: none; width: 188pt;" width="250">71</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc670kxzre2-vrf-isi-pompasi-dis-unite/">FDC670KXZRE2 VRF Isı Pompası Dış Ünite</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC950KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc950kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:13 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1170</guid>

					<description><![CDATA[<p>Mitsubishi&#160;FDC950KXZRE2&#160;VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc950kxzre2-vrf-isi-pompasi/">FDC950KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">475KXZRE2 +<br />
475KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">34HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">16,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">80,8</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">95,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">95,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">29,68</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">23,34</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x2700x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">840</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;2</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø15.88(5/8&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø28.58(1<br />
1/8”)</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~160</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc950kxzre2-vrf-isi-pompasi/">FDC950KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC900KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc900kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:13 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1169</guid>

					<description><![CDATA[<p>Mitsubishi FDC850KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc900kxzre2-vrf-isi-pompasi/">FDC900KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">450KXZRE2 +<br />
450KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">32HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">10,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">64,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">90,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">90,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">28,94</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">22,78</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x2700x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">744</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;2</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø15.88(5/8&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø28.58(1<br />
1/8”)</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~160</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc900kxzre2-vrf-isi-pompasi/">FDC900KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC850KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc850kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:13 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1168</guid>

					<description><![CDATA[<p class="text-uppercase alt-font text-extra-dark-gray margin-20px-bottom font-weight-700 md-w-100 justify-content-between">Mitsubishi FDC850KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc850kxzre2-vrf-isi-pompasi/">FDC850KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">400KXZRE2 +<br />
450KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">30HP</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">10,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">62,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">85,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">85,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">26,03</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">21,15</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x2700x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">744</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;2</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø15.88(5/8&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø28.58(1<br />
1/8”)</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~160</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc850kxzre2-vrf-isi-pompasi/">FDC850KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>FDC800KXZRE2 VRF Isı Pompası</title>
		<link>https://mitsubishiheavyklimalar.com/fdc800kxzre2-vrf-isi-pompasi/</link>
		
		<dc:creator><![CDATA[mitsubishi heavy klima sistemleri]]></dc:creator>
		<pubDate>Tue, 09 Dec 2025 12:04:13 +0000</pubDate>
				<guid isPermaLink="false">https://mitsubishiheavyklimalar.com/?post_type=product&#038;p=1167</guid>

					<description><![CDATA[<p>FDC800KXZRE2 VRF Isı Pompası Dış Ünite</p>
<p>Standard Isı Pompası VRF Dış Ünite</p>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc800kxzre2-vrf-isi-pompasi/">FDC800KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<table border="0" width="752" cellspacing="0" cellpadding="0">
<colgroup>
<col width="146">
<col span="3" width="112">
<col width="270"> </colgroup>
<tbody>
<tr>
<td colspan="3" width="370" height="20">Kombinasyon (FDC)</td>
<td width="112">&nbsp;</td>
<td width="270">400KXZRE2 +<br />
400KXZRE2</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Nominal kapasite</td>
<td width="112">&nbsp;</td>
<td width="270">28</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Güç kaynağı</td>
<td width="112">&nbsp;</td>
<td width="270">3<br />
Faz 380-415V, 50Hz</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Başlangıç Akımı</td>
<td width="112">A</td>
<td width="270">10,0</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Maks. Akım</td>
<td width="112">A</td>
<td width="270">60,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Nominal kapasite</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">80,0</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">80,0</td>
</tr>
<tr>
<td rowspan="2" width="146" height="40">Güç Tüketimi</td>
<td colspan="2" width="224">Soğutma</td>
<td rowspan="2" width="112">kW</td>
<td width="270">23,12</td>
</tr>
<tr>
<td colspan="2" width="224" height="20">Isıtma</td>
<td width="270">19,52</td>
</tr>
<tr>
<td width="146" height="20">Dış Boyutlar</td>
<td colspan="2" width="224">YxGxD</td>
<td width="112">mm</td>
<td width="270">2052x2700x720</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Net Ağırlık</td>
<td width="112">kg</td>
<td width="270">744</td>
</tr>
<tr>
<td width="146" height="20">Soğutucu Akışkan</td>
<td colspan="2" width="224">Tipi&nbsp;</td>
<td width="112">&nbsp;</td>
<td width="270">R410A</td>
</tr>
<tr>
<td width="146" height="20">Akışkan Şarjı</td>
<td colspan="2" width="224">&nbsp;</td>
<td width="112">kg</td>
<td width="270">11.5&#215;2</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Likit Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø15.88(5/8&#8243;)</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Emme Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø31.75(1<br />
1/4&#8243;) [ø34.92(1 3/8&#8243;)]</td>
</tr>
<tr>
<td width="146" height="20">Boru Bağlantıları</td>
<td colspan="2" width="224">Basma Gaz Hattı</td>
<td width="112">mm(in)</td>
<td width="270">ø28.58(1<br />
1/8”)</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Kapasite Bağlantı Aralığı</td>
<td width="112">%</td>
<td width="270">50~160</td>
</tr>
<tr>
<td colspan="3" width="370" height="20">Bağlanabilir İç Ünite Sayısı</td>
<td width="112">&nbsp;</td>
<td width="270">80</td>
</tr>
</tbody>
</table>
<p><a rel="nofollow" href="https://mitsubishiheavyklimalar.com/fdc800kxzre2-vrf-isi-pompasi/">FDC800KXZRE2 VRF Isı Pompası</a> yazısı ilk önce <a rel="nofollow" href="https://mitsubishiheavyklimalar.com">mitsubishi heavy klima</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
